RAID & Server Data Recovery for Houston Businesses

    Short answer

    Do not start another rebuild. Label the drive order, leave the array powered down, and bring every member disk. We image each disk read-only, reconstruct the array offline, and quote a fixed price after the $50 same-day evaluation.

    Lost a RAID array? Multiple drives failed at once? NAS won't mount? Our lab rebuilds RAID 0, 1, 5, 6, 10, JBOD, and proprietary arrays from Synology, QNAP, Dell EMC, HP, and Drobo. Emergency service for production-down situations.

    • RAID 0, 1, 5, 6, 10, 50, 60, JBOD
    • Synology, QNAP, Dell, HP, Drobo, Buffalo
    • Failed rebuilds & double-disk failures
    • VMware / Hyper-V virtual disk recovery
    • Database recovery (SQL, Exchange)
    • 24/7 emergency response for businesses

    What to do (and not do) when a RAID fails

    When a RAID array degrades or fails, the worst thing you can do is keep writing to it or 'try a rebuild' without a full sector-level clone. We've seen recoverable arrays destroyed by one wrong rebuild. Power down the server, label every drive in order, and call us — (281) 694-1425.

    How we rebuild your array

    Every drive gets imaged sector-by-sector to fresh media. We then reconstruct the array virtually using its original parameters (stripe size, parity rotation, drive order) and extract your data without touching the originals. This is the only safe way to recover a failed RAID.

    NAS, virtualization, and database recovery

    Synology and QNAP NAS units use proprietary on-disk formats — we have the tools and experience to handle SHR, BTRFS, and ZFS layouts. For virtualized environments, we recover VMDK and VHDX files from broken datastores, then mount and extract guest data. SQL, Exchange, and Postgres databases are reassembled and verified before delivery.

    RAID 0, 1, 5, 6 and 10 failure modes in plain terms

    RAID 0 stripes data across disks for speed with no redundancy: one disk fails and everything is gone. Recovery depends on repairing or imaging the failed member. RAID 1 mirrors two disks: it survives one failure, but both disks can fail together from age, power surges or a shared controller fault. RAID 5 spreads parity across the disks so it survives one disk failure — but only one. A second failure during a rebuild is the classic RAID 5 disaster. RAID 6 uses double parity and survives two failures, at the cost of capacity and write speed. RAID 10 mirrors pairs of disks and stripes across the pairs: it survives one disk per mirror pair, but losing both sides of the same pair takes the array down. Which disks failed matters as much as how many.

    Why a forced rebuild or re-adding a dropped drive can overwrite parity

    When a controller drops a disk out of the array, that disk stops receiving writes. Forcing it back online, or 're-adding' it, tells the controller to treat stale data as current. The controller then recalculates parity from a mix of old and new data — and writes that wrong parity across every member. The corruption is silent: the array mounts, but files come back damaged. The same logic applies to forcing a rebuild onto a replacement disk before the remaining members are imaged. A rebuild is a write operation across the whole array; if another disk has unreadable sectors, the rebuild stalls or completes with holes. Imaging every member first keeps a safe copy before anyone writes to the array again.

    What to record before you power down

    A few notes taken before shutdown can save hours of reconstruction work: • The RAID level and the controller or NAS make and model. • The slot number of every disk, labelled on the disk itself before removal. • Which disks the controller reported as failed, foreign or offline, and in what order events happened. • Any recent rebuild attempts, and whether they completed or aborted. • The exact error messages or LED patterns shown. • Whether the array held virtual machines, databases or encrypted volumes, and any passphrases. Photograph the disk bays and the controller's event log screen if you can. Then power down and leave the array off.

    Hardware RAID vs software RAID: why the controller's metadata matters

    Dell PERC, HP Smart Array, LSI/Broadcom and similar hardware controllers keep the array's recipe in their own metadata: the RAID level, stripe size, parity or mirror rotation, the order the members sat in, where each member's data starts, and which disks the controller marked failed, foreign or offline. Reconstructing the array means reading that metadata and applying the same parameters. If the controller is dead, or its configuration has been cleared or overwritten, the layout has to be worked out from the member disks instead — slower, and the reason we ask for the controller make, model and any screenshots of its management screen. Windows Storage Spaces, Linux mdadm, ZFS and BTRFS pools keep that information on the disks rather than on a card. mdadm writes a superblock to every member recording the array UUID, device order and layout; Storage Spaces records the pool and its layout in its own metadata; ZFS labels each disk with the pool's topology. That usually makes the layout easier to read back. The complication is the stack underneath — mdadm arrays often sit under LVM and then a filesystem, Storage Spaces can span mismatched disk sizes, and a Synology SHR volume is mdadm under LVM under a filesystem. Each layer has to be rebuilt in order, which is why the exact software and version matters as much as the disk labels.

    Servers and virtualization: VMware ESXi and Hyper-V

    Virtual machines add a layer under the filesystem. An ESXi host normally stores VMs as .vmdk files on a VMFS datastore; Hyper-V stores them as .vhdx files on an NTFS or ReFS volume; a NAS may present storage to either as an NFS or iSCSI target. When the array underneath fails, the work runs in order — rebuild the array, then the datastore or volume, then the virtual disk, then the files inside the guest. A VM that will not boot can still hold intact data, so a guest that won't start is rarely a lost case. Tell us which hypervisor and version you were running, whether the storage was VMFS, a Hyper-V volume or a NAS share, how many hosts shared it, whether the VMs were thin or thick provisioned, whether any snapshots or checkpoints were open when the failure happened, and whether guest encryption such as BitLocker, FileVault or LUKS was in use. If a host still boots, photograph or export the datastore list and any storage error messages before powering down. Keep encryption keys and passphrases with the case: a virtual disk can be rebuilt, but an encrypted guest cannot be opened without its key.

    After recovery: RAID is not a backup

    RAID keeps a service running when a disk fails. It does not protect you from the things that actually destroy data: a rebuild that goes wrong, a controller that loses its configuration, ransomware, an accidental delete, a flood, or someone restoring over the wrong folder. All of those are written to every member disk at once, and the array stores the damage faithfully. Once your files are back, the array is worth rebuilding — but not as your only copy. What to change afterwards: • Keep a copy that is not permanently attached to the array — an external disk connected only for backups, or a cloud copy you can restore from. • Make the backup automatic, then prove it by restoring a single file. A green status in a console is not a restore. • Back up what people forget: the RAID or controller configuration, the hypervisor inventory and datastore layout, the NAS volume settings, and the encryption keys and passphrases. Losing those turns a routine rebuild into a reconstruction. • Decide in advance what the first ten minutes look like after the next alarm: stop writes, label the disks by bay, leave the array powered down, and call before anyone rebuilds. If you want a second opinion on where your copies should live, ask when you collect your media.

    Urgent data loss? Do this first

    1. Stop using the device. Don't run recovery software, CHKDSK, or a RAID rebuild or re-initialize.
    2. Power down a drive that is clicking, beeping or overheating.
    3. RAID or NAS: label each disk with its bay order, and don't swap disks.
    4. Servers or QuickBooks: don't restore a backup over the original or reinstall anything.

    What to bring to drop-off: servers and NAS

    If you can bring the array to us, these are the things that save time at intake:

    • Every member disk, marked with the slot or bay it came from — label the drive body, not the circuit board.
    • The RAID controller, HBA or backplane if it is practical to remove; otherwise the exact make, model and firmware version.
    • The NAS enclosure and its original power adapter if the unit is small enough to carry, plus any credentials the unit itself needs.
    • Any disk added during the failure, and the disk the controller marked failed — kept separate and identified.
    • Written notes: RAID level, error messages, LED patterns, the order events happened in, and every rebuild or import you attempted.
    • Encryption keys or passphrases if volumes were encrypted (BitLocker, FileVault, LUKS, NAS volume encryption).

    Pack the disks in an anti-static bag and cushion them well. The drop-off page carries the full packing checklist and a printable intake slip.

    Not sure what to do next?

    Check your symptoms before trying anything else, call us, or arrange pickup, drop-off or mail-in.

    Last updated · Reviewed by the Kingwood & Atascocita Data Recovery lab team · (281) 694-1425

    Frequently Asked Questions

    Two drives failed in my RAID 5 — is the data gone?

    Not necessarily. Often the 'second failure' is partial, and we can image enough of each drive to reconstruct the array. Don't attempt a rebuild — call us first.

    How long does RAID recovery take?

    Most arrays are reconstructed and delivered in 3–7 business days. Emergency same-day service is available for production-down situations.

    Can you recover a Synology / QNAP NAS?

    Yes — Synology SHR/SHR-2, QNAP, Drobo BeyondRAID, and ZFS / BTRFS arrays are all in our wheelhouse.

    Do you sign NDAs?

    Always. Business and legal data recovery is the majority of our work — every job is confidential and handled by background-checked technicians in-house.

    The controller says a disk is 'foreign' or 'offline' — should I import or force it online?

    No. A dropped disk holds stale data, and forcing it back makes the controller recalculate parity from a mix of old and new blocks, silently corrupting the array. Power down and have the members imaged first.

    Can you recover a RAID 0 with one failed disk?

    Sometimes. RAID 0 has no redundancy, so recovery depends on repairing or imaging the failed member well enough to read its stripes. The odds depend entirely on what is wrong with that disk — evaluation answers that.

    The server wants to initialize the array — what happens if I say yes?

    Initialization writes new RAID metadata over the old layout and can erase the information needed to reconstruct the array virtually. Decline it, power down, and keep the disks in order.

    Do you need the server or RAID controller as well as the disks?

    The labelled disks are the essential part. The controller model and configuration details help us match stripe size and parity rotation, so note them down or bring the controller or enclosure if practical.

    Does it matter whether my array was hardware RAID or software RAID?

    It changes what we need from you. A hardware controller (Dell PERC, HP Smart Array and similar) keeps the array layout in its own metadata, so the controller model and configuration notes matter. Software arrays — Windows Storage Spaces, Linux mdadm, ZFS or BTRFS — record the layout on the disks themselves. Either way, label the disk order and note the software or controller version.

    My virtual machines were on a VMware ESXi datastore. What should you know first?

    Whether the datastore was VMFS, a Hyper-V volume or a NAS share; how many hosts shared it; whether the VMs were thin or thick provisioned; whether snapshots or checkpoints were open when it failed; and whether guests used BitLocker, FileVault or LUKS. If the host still boots, photograph the datastore list and storage errors before shutting down.

    Submit Your Recovery Case – $50 Same-Day Evaluation

    Fill out the form below and our Kingwood & Atascocita data recovery specialist will contact you within the hour.